Model 2620 AC Leakage Current Probe

The Model 2620 measures leakage current shunted to ground caused by insulation faults. It enables the operator to locate failures when they occur, or anticipate them before they occur, without shutting down equipment or spending hours troubleshooting.

It is designed specifically for locating low current faults on high current loads. The detector is a sensitive nickel alloy AC current transformer capable of measuring differential or leakage current as low as 500ľA, and may be used to measure current up to 400A continuous duty.

The Model 2620 provides two output ranges: 1mV/mAac or 1mV/Aac. The output leads are terminated with standard 4mm banana plugs capable of interfacing with any standard multimeter. With its 4" jaw opening and range of 500ľA to 200A, the Model 2620 provides a versatile way to analyze unbalanced current measurements, leakage values on grounding conductors and ground loop currents.

Ground Resistance Tester

Features

  • Very high sensitivity
  • Differential or leakage current from 500ľA Current up to 400A
  • Two switch-selectable measurement ranges: 4AAC / 400AAC
  • Large inside jaw diameter allows use on large or multiple conductors
  • Work with single-, dual- and three-phase networks
  • Connect directly to DMMs on mV or Vac range

Applications

  • Preventive maintenance
  • Equipment troubleshooting on electrical distribution systems
  • High accuracy low-current measurements
  • Measure fault currents on three-phase, three-wire systems
  • Industrial troubleshooting checks

Technical Specification

ELECTRICAL
Current Range
4A Range - 500µA to 4A
400A Range - 500µA to 400A
Output Signal
1mV/mA(4V max.)
1mV/A(4V max.)
Accuracy 500µA to 10mA
3% of Reading±1mV
-
10mA to 100mA
0.5% of Reading±0.5mV
-
100mA 4A
0.5% of Reading±0.5mV
-
500mA to 10A
-
0.5% of Reading±0.5mV
10A to 100A
-
0.35% of Reading±0.5mV
100A to 400A
-
0.35% of Reading±1mV
Phase Shift 10mA to 100mA
<15°
-
100mA to 4A
<10°
-
10A to 100A
-
<1°
100A to 400A
-
<0.6°
Load Impedance(DMM) 1MOhm min. 1MOhm min.
Frequency Range 48 to 1000 Hz 48 to 1000 Hz
output Termination 5ft(1.5m) lead with 4mm safety banana plugs 5ft(1.5m) lead with 4mm safety banana plugs
MECHANICAL
Dimensions 11.22 x 6.89 x 1.77 " (285 x 175 x 45mm)
Jaw Opening 4.4" (112mm)
Maximum Conductor Size 4.4" (112mm)
Weight 2.87 lbs(1300g)
ENVIRONMENTAL
Operating Temperature -14° to 131°F (-10° to 55°C); 0 to 85% RH (non-condensing)
Storage Temperature -14° to 131°F (-10° to 55°C); 0 to 85% RH (non-condensing)
SAFETY
Safety Rating EN61010-2-032, 600V Cat.III
Double Insulation Yes
CE Mark Yes