Duncan Instruments Canada Ltd
Duncan Instruments Canada Ltd.
Electronic Measurement Solutions since 1968
Home  Products  Services  Rental  Contact Us 
   Search Our Site   
1-877-742-4448
Duncan Instruments Canada Ltd
Join our mailing list
Products
ARB /Function Generators
Battery Testing
Breadboard
Data Logging
Electrical Insulation Testing
Electrical Testers
Environmental Instruments
Fused Test Leads
Ground Resistance Tester
LAN Speed Test
Low Resistance Ohmmeter
Oscilloscope
Power Analyzers
Power Quality Analysis
Power Supplies
Resistance Boxes
Tachometers/Stroboscopes
Transformer Testing
Universal Programmers
Technical Articles
Insulation Resistance Tester
Low resistance ohmmeter / microohmmeter / micro-ohmmeter
Arbitrary Waveform Generator
Calibration Service
Radiation Detector
Variable Transformer
Tachometer

 



Model 507 Current Pulse Generator

Features:

  • Peak Outputs to 25 Amps
  • 2 / 4 / 8 Channel Models
  • Independent, Digitally Controlled Outputs
  • Compliance Voltage to 45 V
  • Selectable Delay and Pulsewidth
  • Quick Recall of up to 12 System Configurations
  • RS232 Computer Interface
  • On-Screen Menus and Help
  • Single Shot and External Trigger Modes
  • TTL Synch Signal Output
  • Rackmount Available


The Model 507 with independent outputs, provides digitally controlled current pulses with currents from 0 to 25 Amps and pulsewidths from 0.1 to 100 msec. The Model 507 incorporates unique design features that make it the ideal signal generator for airbag squib and initiator testing, fuse testing and laser trigger applications.


Spefication    
Delays Outputs
Channels 2 / 4 / 8 independent outputs, with digitally controlled current delay and pulse width Impedance 1.405 ohms
Delay 0 to 99.9999998 sec Slew Rate 2.5A/µs
Pulsewidth 0.1 ms to 100 ms Overshoot < 100mA + 10% of pulse amplitude
Resolution 200 ns Amplitude 0-25A with 50mA resolution
Accuracy 100 ns + .0001 x delay Bank Capacitance 24000 µF
Timebase 5 MHz, 25 PPM crystal oscillator Peak Current 25A per channel
RMS Jitter 100 ns max DC Current Limit 100 mA (each channel)
Trig Delay Ext Trig to T0 < 10 µs    
External Trigger/Delays Internal Rate Generator
Rate Dc to 1/(75 µs + largest delay + period) Modes Single shot, external trigger.
Threshold 3 VDc (3 mA into optoisolator) RMS Jitter 100 ns
Trigger Slope Rising or falling time    
Impedance 1000 ohms    
Impedance 1000 ohm    
Computer Interface General
RS232 9600 Baud. All instrument functions and settings may be controlled over the interface bus Storage Storage for 12 complete configurations, may be stored and recalled from the front panel or the computer interface.
Threshold 0.2 to 15VDC Dimensions 7.5" x 9.0" x 4.0"
Maximum Input Voltage 60V Peak Weight 10 lbs
Resolution 10mV Power 20 watts @ 120 or 220V AC
Polarity Active High/Active Low    
Function Pulse Inhibit or Output Inhibit    
Channel Behavior Global w/ Individual Channel Enables    
Internal Rate Generator    
Rate 0.0002 Hz to 20.000 Mhz (40 MHZ optionl)    
EEE 488 STD Optional    
GPIB Optional    
   
Instrument selection
END USER STATEMENT Form - PDF file


Last modified May 26, 2010.
Home | Products | Services | Software | Contact Us