| Specifiction |
| |
Function |
Measuring Range |
Accuracy |
| AC Current |
600A a.c. |
0-600.0A |
±2.0%rdg±5dgt(50/60Hz) |
| Peak 1500A |
±3.5%rdg±5dgt(40~500Hz) |
| CF=2.5@600A |
±5.5%rdg±5dgt(500~1kHz) |
| CF=3.0@500A |
* Add 2% at CF>2 |
| 1000A a.c. |
0-1900.0A |
±2.0%rdg±5dgt(50/60Hz) |
| Peak 1500A |
±3.5%rdg±5dgt(40~500Hz) |
| CF=2.5@600A |
±5.5%rdg±5dgt(500~1kHz) |
| CF=3.0@500A |
* Add 2% at CF>2 |
| DC Current |
600A d.c. |
0-600A |
±1.5%rdg±5dgt |
| 1000A d.c. |
0-1000A |
| AC Voltage |
6/60/600V a.c. |
0-600.0V |
±1.5%rdg±4dgt (50/60Hz), ±3.5%rdg±5dgt (40~400Hz)
|
| DC Voltage |
600mV/6/60/600V |
0-600.0V |
±1.0%rdg±5dgt |
| Resistance |
600/6k/60k/600k/6M ohm |
0-6.000M ohm |
±1.0%rdg±5dgt |
| 60M ohm |
6.000M-60.00M ohm |
±5%rdg±8dgt |
| Cont Buzzer |
0-600.0 ohm |
sounds at 100 ohm or less |
| Diode |
Test voltage: 0-2V |
| Capacity |
40nF |
0.01µF - 4000µF Auto-ranging |
±2.5%rdg±20dgt |
| 400nF |
| 4µF |
| 40µF |
| 400µF |
N/A |
| 4000µF |
N/A |
| Frequency/DUTY |
ACA |
40Hz-400Hz |
±0.5%rdg±5dgt |
| ACV |
1Hz-10kHz |
| 0.1-99.9% (Pulse width/Pulse period) |
±2.5%rdg±5dgt |
| Temperature |
°C |
-50°C ~ 0°C |
±5°C±3dgt |
| 0°C ~ 150°C |
±3°C±2dgt |
| 150°C ~ 700°C |
±2%±2dgt |
| °F |
-58°F ~ 32°F |
±9°F±3dgt |
| 32°F ~ 302°F |
±5°F±2dgt |
| 302°F ~ `192°F |
±2%±2dgt |
| General Specification |
| Power source |
DC3V/ R03(UM-4) x 2pcs |
| Temperature& humidity |
23°C±5°C , relative humidity accuracy
guaranteed 85% or less (no condensation) |
| Operating temperature |
0°C~40°C , relative humidity 85% & humidity
range or less (no condensation) |
| Storage temperature |
-20°C~ 60°C , relative humidity
85% & humidity range or less (no condensation) |
| Applicable Standards |
IEC 61010-1:2001- Measurement CAT. IV 600V Pollution
degree 2... |
| Conductor size |
approx. 40mm |
| Weight |
approx 310 g |
| Accessories |
Test Leads -TL75 / 1 set, K-type Temperature Probe
MODEL8216/1 set, Battery R03.UM-4./ 2pcs, manual and case |