Duncan Instruments Canada Ltd
Duncan Instruments Canada Ltd.
Electronic Measurement Solutions since 1968
Home  Products  Services  Rental  Contact Us 
   Search Our Site   
1-877-742-4448
Duncan Instruments Canada Ltd
Join our mailing list
Products
ARB /Function Generators
Battery Testing
Breadboard
Data Logging
Electrical Insulation Testing
Electrical Testers
Environmental Instruments
Fused Test Leads
Ground Resistance Tester
LAN Speed Test
Low Resistance Ohmmeter
Oscilloscope
Power Analyzers
Power Quality Analysis
Power Supplies
Resistance Boxes
Tachometers/Stroboscopes
Transformer Testing
Universal Programmers
Technical Articles
Insulation Resistance Tester
Low resistance ohmmeter / microohmmeter / micro-ohmmeter
Arbitrary Waveform Generator
Calibration Service
Radiation Detector
Variable Transformer
Tachometer

 



POLAR STAR Three Phase Energy and Power Qulity Analyzer

Polar Star is a State-of-the-art device equipped with new functions for monitoring energy consumption and for advanced energy and quality analysis. This device is able to measure, display, process and transmit all the parameters of a plant.

  • 4 independent current inputs with a 0.25%+0.05FS accuracy
  • 3 voltage measuring channels up to 600V Cat III, with a 0.25%+0.05FS accuracy
  • 6 electrical systems which can be analyzed: (i) Single-phase type; (ii)two-phase type; (iii) three-phase with 3 leads (unbalanced type); (iv) three-phase with 4 leads (unbalanced type); (v) three-phase with 3 leads (balanced thpe); (vi)three-phase with 4 leads (balanced type);
  • Switching power supply, 90÷230Vac ~ 50-60Hz, 90÷300Vdc
  • Energy quality analysis through measuring of: current and voltage harmonics (all 7 input channels) up to the 31st order; power and micro-power blackouts* Dips (voltage losses)* Swells (overvoltages)* EN50160 test (reference standard for energy quality)* Event data logger (5 alarms, 5 dips, 5 swells, 5 interruption)* graphic display of trends (time progress) of 5 selectable measures* energy measurement in 4 time periods (tariffs)* (tariffs can be freely set)
  • Automatic test connection for checking the electrical connections
  • Automatic option recognition
  • Software available for TOP model to monitoring directly the Polar Star


Function
BASE model
TOP model
ELECTRICAL CONNECTIONS
Single phase
Two-phase
Three-phase / 4 wires balanced
Three-phase / 4 wires unbalanced
Three-phase / 3 wires balanced
Three-phase / 3 wires unbalanced
POWER SUPPLY
AC 90-230VAC ±10% 50-60Hz 8VA
DC 90-300 VDC ±10% 8W
DC (with dedicated option) 24-48 VDC
INPUT
Voltage input characteristics: 3 + common
Norminal range phase-neutral 100-400VAC 40-70Hz
Norminal range phase-phase 17-700 VAC 40-70Hz
Insulation 480 V CAT III
Current inputs characteristics(CT ratio/5) 4 independents (3 + I neutral)
Shunt inputs
Insulated inputs (4 internal CTs)
MEASUREMENTS
V-I-P-Q-A-F-PF-THD%
inst/min/max/avg valus - kWh
Harmonics up to 31th order
Voltage unbalance
Neutral Current
Voltage Interruption (also of the power supply)
Voltage Dips
Voltage Swells
Graphic Trends
Tariff band
Cost management of kWh tariffs band
MECHANICAL CHARACTERISTICS
Case dimension 9with modules option)
96x96x58(x97) mm
Internal electrical panel size (with modules option)
91x91x40 (x 78) mm
IPindex
IP65(front panel) IP30 (rear case)
Type of case material
ABS V0
4 key silicone keyboard
 
ACCURACY for BASE and TOP mode
Voltage 0.25%
Current 0.25%
Power 0.25%
 
OPTIONS for BASE and TOP model
RS485 communication
2 digital outputs
2 digital inputs
24-48 VDC power supply
Wireless communication
 
Standards for BASE and TOP model
IEC EN61010 (safety requirements for electrical equipment for
measurement, control and laboratory use)
 
IEC EN61326 /A1 /A2 /A3 (EMC requirements for electrical
equipment for measurement, control and laboratory use)
 
MODEL for BASE and TOP model
POLAR STAR BASE code 4ABAA
POLAR STAR TOP code 4ABAB
POLAR STAR TOP with RS485 option code 4ABAC

POLAR STAR GATE

(TOP+RS485 option+USB/485 converter+SW)

code 4ABAD
 
ACCESSORY for BASE and TOP model
USB/485 converter code 4ABAE
RS485 communicaiton option code 4A485
2 ALM option (two digital output) code 4AALM
2 DIGIN option (two digital input) code 4ADIN
24-48 VDC option code 4AVDC
 
Expension Slots

2 slots for plug & play option modules. The expansion modules are automatically recognised by the meter and the related menus and function will be immediately available after rebooting the instrument.