Duncan Instruments Canada Ltd
Duncan Instruments Canada Ltd.
Electronic Measurement Solutions since 1968
ISO 9001
 
1-877-742-4448
Products

 

KEW 6310 - Power Quality Analyzer

To Control Completely Power Quality

Features

-Measurements:

Energy
Quality
  • Voltage, Current, Frequency
  • Active power, Reactive power, Apparent power
  • Active energy, Reactive energy, Apparent energy
  • Power factor
  • Neutral current
  • Demand
  • Harmonic
  • Swell & Dip
  • Instantaneous Stop
  • Transients/Over Voltage
  • Inrush Current
  • Unbalance Rate
  • Flicker
  • Phase Advance Condense

-Wiring connections:

  • 1P 2W
  • 1P 3W
  • 3P 3W
  • 3P 4W
--4 Voltage inputs, 4 Current inputs
- Expanded memory up to2GB
- PC software (PQA MASTER) supplied
- Display Waveform and Vector, and can confirm the wiring connection
- Safety Standard IEC61010-1 CAT III 600V
Specification

Voltage

Range 150 / 300 / 600 /1000V
KEW 6310
KEW 6310
6310-01
  • Instrument KEW6310
  • 3 x 500A Clamps (Ø40 mm)
  • Test Lead : 4pcs
  • USB Cable
  • Power cord
  • Compact Flash card 128MB
  • CF Card reader
  • Carrying bag, input terminal plate (6-kind)
  • PC Software
  • Batteries 6, cable maker x 32
  • Quick manual
Accuracy |0.3%rdg0.2%f.s. (sine wave, 45~65Hz)
Current Range
  • 8128 ( 50A type ) : 1 / 5 / 10 / 20 / 50A
  • 8127 ( 100A type ) : 10 / 20 / 50 / 100A
  • 8126 ( 200A type ) : 20 / 50 / 100 / 200A
  • 8125 ( 500A type ) : 50 / 100 / 200 / 500A
  • 8124 ( 1000A type ) : 100 / 200 / 500 / 1000A
  • 8129 ( 3000A type ) : 300 / 1000 / 300
Accuracy 0.3%rdg0.2%f.s. + Accuracy of Clamp sensor (sine wave, 45~65Hz)
Frequency meter range 40.00~70.00Hz
Harmonic 1-63rd
Transient Sampling at every 100 Micro Second
Power Supply AC100 ~ 240V±10%, Dry battery (LR6, 9V) or NiMH battery (7.2V)
Communication USB Ver 1.1
Recording Data Compact Flash Card (Capacity 32/64/128/256/512/1GB)
Indication renewal Every 1 sec
Temperature& Humidity 23C±5C, less than 85% RH (without condensation)
Operating temperature and humidity ranges 0~+40C, less than 85% RH (without condensation)
Storage temperature and humidity ranges -20~+60C, less than 85% RH (without condensation)
Dimension & Weight 175(L)120(W)65(D) mm , 900g (including batteries)
   
 
Set Model
Model Clamp Sensor
KEW6310-00 -
KEW6310-01 8125 (500A, ø40) x 3
KEW6310-03 8124 (1000A, ø68) x 3
KEW6310-05 8126 (200A, ø40) x 3
KEW6310-07 8127 (100A, ø24) x 3
KEW6310-09 8128 (5A, ø24) x 3
KEW6310-12 8129 (3000A, ø150) x 3, Flex.ible clamp sensor
   

Need more information about 6310?

Download Datasheet - PDF file

 



Instrument selection

  Power Analyzers

 
Last modified: February 09, 2010.