MD 9270 Leakage Clamp TRMS Meter With Power Functions


Features:

  • CSA Approved
  • TRMS: accurate measurements on sinusoidal and non-sinusoidal signals.
  • Jaw size: 31 mm.
  • Shielded Jaw: shielded jaw allows the clamp meter to be used in the noisiest environments.
  • Accurate: readings of AC current with an accuracy of 0.8 % and a base resolution of 0.01 mA and voltage with an accuracy of 0.5 % and a base resolution of 0.1 V.
  • Power: measures various power parameters (active, reactive, apparent power, THD, PF, phase displacement).
  • Intelligent loss analysis: complex algorithms detect loss and allow determining possible reasons for current loss.
  • Harmonics: measures current or voltage harmonic components and a percentage value of a harmonic up to the 49th.
  • THD and PF: dual display allows readings to be displayed along with Total Harmonic Distortion (THD) or Power Factor (PF).
  • Peak value: the peak value of the waveform or crest factor can be displayed.
  • MAX/MIN/HOLD mode: displays maximum, minimum or average measured value

MD 9270 Standard Set:

  • Current clamp MD 9270
  • Test lead with probe
  • 2 pcs 1.5 V battery, type AAA 2 pcs
  • Pouch
  • Instruction manual
Specification
Function Range Accuracy
AC Current 40.00 mA, 400.0 mA, 4000 mA (0.8% of rdg+3 dgt)
40.00 A (1.0% of rdg+3 dgt)
150.0 A (2.0% of rdg+5 dgt)
AC Voltage 250.0 V, 600.0 V (0.5% of rdg+2 dgt)
THD 0 ~ 99.9%

(2.0 % of rdg+3 dgt)

100 ~ 999 % (3% of rdg+5 dgt)
Crest Factor 1.0 ~ 2.99 (2.0% of rdg+2 dgt)
3.00 ~ 9.99 (3.0% of rdg+5 dgt)
Peak Value 0 ~ 150.0 A (3.0% of rdg+3 dgt)
0 ~ 600.0 V (3.0% of rdg+3 dgt)
Power Factor 0.00 ~ 1.00 (1.0% of rdg+0.01)
Phase -180° ~+1800° (1.0% of rdg+0.4)
Apparent Power 0 ~ 9999 VA From (1.0% of rdg+0.03) to (1.0% of rdg+3)
10 kVA ~ 999.9 kVA From (2.0% of rdg+0.03) to (1.0% of rdg+0.3)
Active Power 0 ~ 9999 W From (1.0% of rdg+0.03) to (1.0% of rdg+3)
10 kW ~ 999.9 kW From (2.0% of rdg+0.03) to (1.0% of rdg+0.3)
Reactive Power 0 ~ 9999 VAr From (1.0% of rdg+0.03) to (1.0% of rdg+3)
10 kVAr ~ 999.9 kVAr From (2.0% of rdg+0.03) to (1.0% of rdg+0.3)
Power Supply 2 x 1.5 V batteries, type AAA
Overvoltage Category CAT III / 600 V, CAT IV / 300 V
Dimensions 212 x 59 x 37 mm
Weight 225 g