| 6300
Multi-Function Digital Multimeter,
Five-inone
DMM |
3 3/4 Auto ranging DMM with Sound Level,
Relative Humidity, Luminance, and Temperature measurements
.The DMM that senses its environment.
|
| Features |
|
|
- Five meters in one. Humidity, Light, Sound, Temperature
plus DMM
- Display reads Humidity and Ambient temperature along
with measurement Value
- Resettable current overload fuses, no need to open
the meter to replace a blown fuse
- Temperature measurement In Fahrenheit or Celsius
- Measures Duty cycle, Frequency and Capacitance
- 3 3/4 digit and 4000 count
- Relative mode and Data hold
- Auto and Manual Ranging
- Auto power-off (Sleep mode)
- Buzzer and flashing light warning when leads are
connected to wrong input or overload condition
- Back lit display
|
|
|
| Specification |
|
| DC Volts: |
Ranges: 400mV, 4V, 40V, 400V, 1000V
|
Best Resolution: 100µV
|
Accuracy: ± (0.7% +2d)
|
Input Impedance: 10MOhm
|
Maximum Input volts: 250V 400mV range
|
1000V DC all other ranges
|
| AC Volts: |
Ranges: 400mV, 4V,40V, 400V, 1000V
|
Best Resolution: 100µV
|
Accuracy: ± (0.8% +3d)
|
± (3.0% +3d) 400m Range
|
± (1.0% +3d) 1000V Range
|
Input Impedance: 10MoHM
|
Maximum Input volts: 250V 400mV range
|
1000V DC all other ranges
|
| DC Current: |
Ranges: 400µA, 4000µA, 40mA, 400ma, 10A
|
Best Resolution: 100pA
|
Accuracy: ± (1.2% +3d)
|
± (3.0% +7d) 4A and 10A ranges
|
Overload Protection: 500mA /250V resettable
|
fuse and 10A/ 250V fuse
|
| Resistance: |
Ranges: 400.0, 4.000K, 40.00K., 400.0K Ohm
|
4.000M, 40.00M oHM
|
Best resolution: 0.1Ohm
|
Accuracy: ± (1.2% +2d)
|
(2.0% +5d) 40M. range
|
Open Circuit Voltage: Approx. 250mV
|
Overload Protection: 250VDC or RMS
|
|
| Capacitance: |
Ranges: 4nF, 40nF, 400nF, 4µF, 40µF, 200µF
|
Best Resolution: 1pF
|
Accuracy: ± (3.0% +3d)
|
Overload protection: 250V DC or RMS
|
| Frequency: |
Ranges: 9.999Hz, 99,99Hz, 999.99Hz, 9.999Khz,
|
99.99KHz, 199,9KHz.
|
Best Resolution: 0.001Hz.
|
Accuracy: ± (1.5% +5d) ranges
|
± (2.0% +5d) 10Hz and 200 KHz
|
Unspecified > 200 KHz
|
Overload Protection: 250V DC or RMS
|
Sensitivity: 0.6V to 3V RMS
|
| Duty Cycle: |
Range: 0.1% to 99.9%
|
Resolution: 0.1%
|
Accuracy: ± 3.0%
|
| Temperature: (Main display) |
Range: 0°C to 40°C (32°F to 104° F)
|
Resolution: 0.1°C or F
|
Accuracy: ± 2°C and ± 4°F
|
| Temperature: (with Thermocouple) |
Ranges: -20°C to 1000°C
|
Resolution: 1°C or F
|
Accuracy:
|
± 5.0% or ±3°C -20°C to 0°C
|
± 1.0% or ±2°C 0°C to 400°C
|
± 2.0% 400°C to 1000°C
|
± 5.0% or ± 6°F -4°F to 32°F
|
± 1.0% or ± 4°F 32°F to 752°F
|
± 2.o% 752°F to 1832°F
|
|
| Continuity Buzzer: |
Open circuit V: 0.5V
|
Buzzer will sound at < 40. resistance
|
| Diode: |
Open Circuit Voltage: 1.5V DC
|
Test Current: 1mA
|
Overload Protection: 250V DC or RMS
|
| Sound level: |
Range: 40dB to 100dB
|
Resolution: 0.1dB
|
Accuracy:±3.5% at 94dB and a 1KHz sine wave
|
Frequency range: 100Hz to 8 KHz
|
| Luminance: |
Ranges: 0 to 4000 lux and 0 to 40,000 (x10
lux )
|
Resolution: 1 lux (x1 lux) and 10 lux (x10
lux)
|
Accuracy: ± (5% +10d) at a color temperature
of 2856K calibrated to a standard Incandescent lamp
|
| General Specifications: |
Relative Humidity:
|
Range: 20~95% Accuracy: ± 5%
|
Operating Temperature:
|
0 to 40°C (32°F to 122°F) with < 70% humidity
|
Dimensions: 7.7” (H) x 3.6”(W) x 2.2” (D)
|
195 x 92 x 55 mm
|
Weight: 14.3 oz
|
Power:3x 1.5V AAA Batteries
|
Accessories: Test Leads, Operator’s manual
and batteries
|
|
Back to the instrument selection
For your price and delivery inquires, application
details comments, and general feedback, please select Feedback Mailbox
|